Magnum-energy MM-AE Series Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Relais Magnum-energy MM-AE Series herunter. Magnum Energy MM-AE Series User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Inverter/Chargers

Owner’s ManualMM-AE SeriesInverter/Chargers

Seite 2 - Contact Information

© 2010 Magnum Energy, Inc.41.0 Introduction1. Inverter Status Indicator - this green LED illuminates to provide information on the inverter’s operatio

Seite 3 - © 2010 Magnum Energy, Inc

© 2010 Magnum Energy, Inc.15. AC Output Connection - AC knockout (output) for hardwiring. 16. AC Input Connection - AC knockout (input) for hardwiring

Seite 4 - SAVE ALL INSTRUCTIONS

© 2010 Magnum Energy, Inc.62.0 Installation2.0 InstallationPre-InstallationBefore installing the inverter, read the entire Installation section. The m

Seite 5 - Table of Contents

© 2010 Magnum Energy, Inc.Figure 6, Basic Installation DiagramACMain PanelMM-AE Series InverterDC disconnect and overcurrent deviceBattery BankAC INAC

Seite 6 - List of Tables

© 2010 Magnum Energy, Inc.2.0 Installation8Locating and Mounting the InverterWARNINGS:• Do not mount the inverter near any fl ammable or combustible fl

Seite 7

© 2010 Magnum Energy, Inc.Safe - Keep any fl ammable/combustible material (e.g., paper, cloth, plastic, etc.) that may be ignited by heat, sparks, or fl

Seite 8 - Appliances and Run Time

© 2010 Magnum Energy, Inc.102.0 InstallationFigure 8, MM-AE Series Inverter/Charger DimensionsMounting holes x4 [¼” (0.25") diameter]10.0"~

Seite 9

© 2010 Magnum Energy, Inc.• DC wires and cables should be tied together with wire ties or electrical tape approximately every 6 inches. This helps im

Seite 10 - Back Side

© 2010 Magnum Energy, Inc.122.0 InstallationThe DC wires must have soldered and crimped lugs, crimped copper compression lugs, or aluminum mechanical

Seite 11 - 1.0 Introduction

© 2010 Magnum Energy, Inc.DC Overcurrent ProtectionFor safety and to comply with NEC (National Electrical Code) electrical code regulations, you must

Seite 12 - 2.0 Installation

© 2010 Magnum Energy, Inc.Disclaimer of LiabilityThe use of this manual and the conditions or methods of installation, operation, use, and maintenance

Seite 13 - MM-AE Series Inverter

© 2010 Magnum Energy, Inc.2.0 Installation14Figure 9, DC Cable to Battery TerminalsDC Cable ConnectionsWhen connecting the DC cable to the battery or

Seite 14

© 2010 Magnum Energy, Inc.Battery Bank WiringWARNING: Lethal currents will be present if the positive and negative cables attached to the battery bank

Seite 15

© 2010 Magnum Energy, Inc.162.0 InstallationCAUTION: The inverter is NOT reverse polarity pro-tected. If this happens, the inverter will be damaged an

Seite 16 - Wiring Guidelines

© 2010 Magnum Energy, Inc.Neutral to Safety Ground BondingThe NEC (National Electric Code) provides the standards for safely wiring AE (house, cabin,

Seite 17 - DC Wiring

© 2010 Magnum Energy, Inc.2.0 Installation18The AC wires inside the AC compartment are #16 AWG with a tem-perature rating of 105° C. All AC connection

Seite 18

© 2010 Magnum Energy, Inc.AC Input WiringYour inverter has an AC transfer feature that passes the AC input power to the inverter’s output. Connection

Seite 19

© 2010 Magnum Energy, Inc.202.0 InstallationAC Output WiringCAUTION: The inverter’s AC output must never be con-nected to an AC power source. This wil

Seite 20

© 2010 Magnum Energy, Inc.2.0 Installation214. Remove about two inches of the insulating jacket from the AC cable, and then separate the three wires a

Seite 21 - Battery Bank Wiring

© 2010 Magnum Energy, Inc.223. Prior to turning on the inverter, make sure all connected loads (e.g., appliances) are switched OFF or disconnected fro

Seite 22

© 2010 Magnum Energy, Inc.3.0 OperationOperating ModesThe MM-AE Series inverter/charger has two normal operating rou-tines; Inverter Mode, which power

Seite 23 - AC Wiring

© 2010 Magnum Energy, Inc.IMPORTANT PRODUCT SAFETY INSTRUCTIONSThis manual contains important safety instructions that must be fol-lowed during the in

Seite 24 - AC Ground

© 2010 Magnum Energy, Inc.3.0 Operation24Standby ModeThe MM-AE Series features an automatic transfer relay and an internal battery charger when operat

Seite 25

© 2010 Magnum Energy, Inc.2. The AC input voltage falls < 85 VAC – the charger reduces the charge current to zero to help stabilize the incoming AC

Seite 26

© 2010 Magnum Energy, Inc.Constant CurrentReducedCurrentReduced VoltageAbsorb volts‘Adj Charge Rate’ SettingIncreased VoltageConstant VoltageMonitored

Seite 27 - Functional Test

© 2010 Magnum Energy, Inc.3.0 Operation27Battery Temperature Sensor Operation - The plug-in Battery Tem-perature Sensor (BTS) is used to determine the

Seite 28

© 2010 Magnum Energy, Inc.Protection Circuitry OperationThe inverter is protected against fault conditions, and in normal usage it will be rare to see

Seite 29 - 3.0 Operation

© 2010 Magnum Energy, Inc.Internal Fault - The inverter continually monitors several inter-nal components and the processor communications. If a condi

Seite 30

© 2010 Magnum Energy, Inc.303.0 OperationProtection ModeThere are fi ve fault conditions that will cause the inverter to shut down: Low Battery, High B

Seite 31

© 2010 Magnum Energy, Inc.Table 6, Inverter Default Settings03 Battery AmpHrs: This setting allows you to input the battery bank size in amp hours. Th

Seite 32 - Absorb Time

© 2010 Magnum Energy, Inc.324.0 Maintenance and Troubleshooting4.0 Maintenance and TroubleshootingRecommended Inverter and Battery CareThe MM-AE Serie

Seite 33 - Temperature reading from BTS

© 2010 Magnum Energy, Inc.4.0 Maintenance and Troubleshooting33Symptom Possible cause Recommended SolutionLow Battery Voltage (the statu

Seite 34

© 2010 Magnum Energy, Inc.• No overcurrent protection for the battery supply is provided as an integral part of this inverter. Overcurrent protection

Seite 35 - Inverter Model

© 2010 Magnum Energy, Inc.345.0 Specifi cationsMODEL MM612AE MM1512AE MM1524AEInverter Specifi cationsInput battery voltage range 9 to 16 VDC 9 to 16 VD

Seite 36 - Factory Default Settings

© 2010 Magnum Energy, Inc. Appendix A - Optional Equipment and Accessories35Appendix - Optional Equipment and AccessoriesThe following Magnum Energy c

Seite 37 - Function Default Settings

© 2010 Magnum Energy, Inc. Appendix B - Battery informationAppendix B - Battery InformationBattery Bank SizingThe size of the battery bank determines

Seite 38 - Resetting the Inverter

© 2010 Magnum Energy, Inc. 37Appendix B - Battery InformationParallel WiringWiring the batteries in parallel increases the total run time the bat-teri

Seite 39 - Troubleshooting

© 2010 Magnum Energy, Inc. Appendix B - Battery Information3812 VDCbattery(100 AH)12 VDCbattery(100 AH)12 volt battery bank (one string of one 12-volt

Seite 40 - 5.0 Specifi cations

© 2010 Magnum Energy, Inc.39 Appendix B - Battery Information24 volt battery bank (one string of four 6-volt batteries wired in series )to 24 VDCinve

Seite 41

© 2010 Magnum Energy, Inc.24 Month Limited WarrantyMagnum Energy, Inc., warrants this MM-AE Series Inverter/Charger to be free from defects in materia

Seite 42 - Battery Confi guration

© 2010 Magnum Energy, Inc. Appendix C - Warranty/Service Information41How to Receive Repair ServiceIf your product requires warranty service or repair

Seite 43 - © 2010 Magnum Energy, Inc. 37

© 2010 Magnum Energy, Inc.Magnum Energy, Inc.2211 West Casino Rd.Everett, WA 98204Phone: (425) 353-8833Fax: (425) 353-8390Web: www.magnumenergy.comPN:

Seite 44

© 2010 Magnum Energy, Inc.ivTable of Contents1.0 Introduction ...1MM-AE Series Models .

Seite 45

© 2010 Magnum Energy, Inc.vList of FiguresFigure 1, MM-AE Series Inverter/Charger ... 1Figure 2, Top Side Features ...

Seite 46 - 24 Month Limited Warranty

© 2010 Magnum Energy, Inc.1.0 Introduction1.0 IntroductionCongratulations on your purchase of an MM-AE Series inverter/char-ger from Magnum Energy, In

Seite 47 - How to Receive Repair Service

© 2010 Magnum Energy, Inc.21.0 IntroductionHow an Inverter/Charger WorksAn inverter takes direct current (DC) from your batteries and turns it into al

Seite 48 - PN: 64-0035 Rev A

© 2010 Magnum Energy, Inc.21346587Figure 2, Top Side FeaturesStandard Features and Benefi tsThe MM-AE Series inverter/charger converts 12 or 24 volts (

Verwandte Modelle: MM-E Series

Kommentare zu diesen Handbüchern

Keine Kommentare