ME-RSA-M Instruction Sheet
Part Number: 64-0023 Rev A 1
Magnum Energy, Inc.
2211 West Casino Rd.
Everett, WA USA 98204
www.magnumenergy.com
Introduction
The ME-RSA-M Remote Switch Adapter allows users to connect external
switches and to remotely turn the inverter on and off from different locations.
The ME-RSA-M requires a “momentary” type of switch and allows multiple
switches in different locations to turn the inverter on and off.
The ME-RSA-M is simple to install and is designed to be used with inverters that
provide a Stack port, such as the ME, MS, MS-AE, and RD Series inverters.
Installation
Refer to Figure 2 for the following steps to install the ME-RSA-M:
1.
Crimp an appropriately sized wire to each butt-splice connector on the
ME-RSA-M adapter, and ensure a tight connection.
Info: The red butt-splice connectors on the ME-RSA-M adapter ac-
cept 22 to 18 AWG wire.
2. Connect the other end of the two wires to one (or more) external on/off
switches. This external switch should be a “momentary” type of switch which
returns to its normal position when released.
3. The ME-RSA-M adapter MUST be plugged into
the Stack port on the inverter
as shown in Figure 1.
Operation Steps
1. The inverter’s ON/OFF button (and on the ME-RC remote control, if connected)
can be used in tandem with the switches connected to the ME-RSA-M.
2. The inverter will alternately turn on or off when either an external switch, a
remote control, or the inverter’s ON/OFF button is alternately pressed.
Info: The charger will continue to function and is not affected by
the ME-RSA-M adapter operation.
Communication Ports
on the Inverter /Charger
Stack
(red )
Magnum Net
(green )
Remote
(blue)
BTS
(yellow)
ME-RSA-M
must be
connected to
the Stack Port
ME-RSA-M
RSA-M