ME AGSAuto Gen StartNetwork Systemwith Inverter and Remotefor Coach GeneratorsOperators Manual
2004 - Magnum Energy, Inc.84 Wire Twisted Pair Cable1234567812 VDC BatteryGENStart/StopSwitchGENHourMeter+-+-Fuse5 AmpStartCommStopGroundGroundFigu
2004 - Magnum Energy, Inc.9Figure 4 - AGS Connector Pin Legend(from left to right)12345678Aux ContactGenerator Stop / PreheatCommon from GeneratorSt
2004 - Magnum Energy, Inc.10The AGS comes preset for voltage, temperature and generatorrun time directly from the factory. Quiet Time is factory pr
2004 - Magnum Energy, Inc.113. Installation5. "QUIET TIME" is a program that prevents the generator fromstarting during specific hours of
2004 - Magnum Energy, Inc.124. OperationThe AGS Remote Control is equipped with a wide range ofeasy-to-use switches and displays, allowing you to qu
2004 - Magnum Energy, Inc.134. OperationWARNING: Set the AGS to "AutoGenSt OFF" beforeservicing the electrical or generator system.NOTE: I
2004 - Magnum Energy, Inc.Weight (Controller) 1 lb (0.5 kg)Weight (Switch) 0.25 lb (0.1 kg)Dimensions (Controller) 3.0 H x 5.2 W x 1.33 D(7.6 cm
2004 - Magnum Energy, Inc.LED INDICATION SYMPTOM OPERATION/SOLUTIONRED Gen won't start. Check Gen start wiring,= GEN FAULT Turn "off"
2004 - Magnum Energy, Inc.167. Warranty36 Month Limited WarrantyMagnum Energy, Inc., warrants the ME Series Auto Gen Start to be free fromdefects in
Templates1/8” Drill Bit5-1/4”4-3/4”2-3/4”3-1/4”Cut Out AreaRemote ControlCutoutRemote Switch (option)2-1/8”1-5/8”1-1/4”7/64” Drill Bit
Magnum Energy, Inc.1111 80th Street SW - Suite 250Everett, WA 98203p: 425.353.8833f: 425.353.8390p/n 64-0005 rev. - 6/04
2004 - Magnum Energy, Inc.ME AGS Operators ManualAuto Gen Start Network Systemwith Inverter and Remotefor Coach GeneratorsTable of ContentsSection
2004 - Magnum Energy, Inc.21. OverviewIMPORTANT SAFETY INFORMATION This product must be installed by a qualified technician inaccordance with all a
2004 - Magnum Energy, Inc.32. ConfigurationFigure 1 - AGS Controller Configuration(DIESEL/GAS and 12/24 V DC Operation)1. Configuring the AGS Contro
2004 - Magnum Energy, Inc.42. ConfigurationTable 1 - Magnum AGS Software Revs (4/2/04)VERSION V 2.0 V 2.1DATE March 1, 2004 March 1, 2004START TYPE
2004 - Magnum Energy, Inc.53. InstallationInstalling the AGS ControllerIn most cases, the Auto Gen Start (AGS) Network System withInverter and Remot
2004 - Magnum Energy, Inc.63. InstallationInstalling the AGS Interior Temperature SensorWARNING: Always check for hidden wires, pipes andcables befo
2004 - Magnum Energy, Inc.73. Installation4. Plug the other end of the 6 wire phone cable into the AGSControllers RJ-11 connector marked "Remo