The AGS comes preset for voltage, temperature and generator
run time directly from the factory. Quiet Time is factory preset
to "OFF" (defeated). For the majority of customers, no adjust-
ments are necessary. If you need to make changes to the
factory adjustments, you can do so by rotating the knobs on
the AGS Controllers front panel (refer to next page)
1. The "START TEMP F" factory setting is set at 75 °F (25 °C).
When the inside coach temperature reaches this point, the
generator will automatically start to power the air condi-
tioner.
NOTE: To change this setting, slowly rotate the knob marked
"START TEMP F" clockwise to increase temperature or counter-
clockwise to decrease temperature. The temperature range is
adjustable from 65 °F to 85 °F (18 °C to 29 °C).
2. The "START VOLTS" factory setting is set at 11 VDC. When
the battery voltage drops to this setting, the generator will
automatically start and recharge the batteries. There is a 2
minute delay once the voltage setting is reached.
NOTE: To change this setting, slowly rotate the knob marked
"START VOLTS" clockwise to increase the voltage or counter-
clockwise to decrease voltage. The range is 10 VDC to 12 VDC.
NOTE: This system is capable of both 12 VDC and 24 VDC
operation. For 24 VDC applications, the value indicated on the
cover is automatically doubled (i.e., 11 VDC equals 22 VDC).
3. The "RUN TIME HOURS" factory setting is set at 2 hours. This
is the length of time the generator will run once the "START
TEMP F" or "START VOLTS DC" setting has been reached and
the generator starts.
NOTE: To change this setting, slowly rotate the knob marked
"RUN TIME HRS" clockwise to increase generator run time and
counterclockwise to decrease generator run time. Generator
run time can be set from 1 to 5 hours.
NOTE: To defeat the Temperature or Voltage Start feature, turn
the adjustment knob fully counter-clockwise (OFF).
4. The AGS Controller has a 24 hour internal clock. When
using the inverters Network Port, the Controllers Clock dial
is defeated. Set the clock with the remote control (page 12).
Once set, the clock will continue to keep time. In the event
of loss of power to the controller, you must reset the clock.