Soft Keys, continued:
Setup –
Configures the inverter/charger. Options include:
• Search
Used to set the search watts at which the inverter will come
out of “sleep” mode. Selections are 3-75 watts.
• LBCO (Low Battery Cut Out)
Used to set the DC voltage level to shut down the inverter
and protect the batteries from over-discharge damage.
Selections are 9.0 VDC, 10.0 VDC and 11.0 VDC. DC volts
must reach and maintain LBCO setting for 2 minutes before
inverter shut down is initiated.
• Battery Size
Used to select the approximate battery bank capacity.
Selections are in 200 amp increments from 200 -1000
amps. Battery capacity is also used to determine absorption
time during battery charging. See Chart 2.
• Battery Charge Rate
Used to set the maximum charge rate during bulk, absorp-
tion or float charge. Selections are in 10 amp increments
from 10% - 100%.
• Battery Type
Used to select battery type for the battery charge profile.
Selections are Gel, AGM (Absorbed Glass Mat), Liquid Lead
Acid (Flooded) and Custom (future). See Chart 1.
• Contrast
Used to adjust the LCD contrast.
• Factory Reset
Restores all settings to factory defaults. press and hold the
switch the switch for 5 seconds. “Reset Complete” will be
appear in the display. See Chart 3.
Tech – (display only)
Reserved for future, this feature is used for troubleshooting
the inverter/charger. Options include FET temp, transformer
temp, battery temp and fault record. Fault record tracks the
last 10 inverter/charger shut down faults.